Specification Matrix

Comparative Material Performance Matrix

Select 2 to 4 glass constructions to compare mechanical properties, regulatory classifications, and processing limits.

Performance Property
Toughened Safety Glass (Tempered)BS EN 12150-1
Laminated Safety & Security GlassBS EN 14449
Insulating Glass Units (Double & Triple IGUs)BS EN 1279 (Parts 1–6)
Safety Classification (EN 12600)Class 1C1 (BS EN 12600: drop height 1200mm)Class 1B1 or 2B2 (BS EN 12600); Class P1A to P5A (BS EN 356 manual attack)Determined by individual glass plies (inner/outer toughened or laminated to BS EN 12600)
Mechanical Bending StrengthCharacteristic tensile bending strength fb,k = 120 N/mm² (float base) / 90 N/mm² (patterned base) vs 45 N/mm² annealed floatEquivalent to constituent panes; structural ionoplast interlayers achieve post-yield structural retention and full shear transferShares wind load between plies via cavity pressure transfer; calculated per EN 16612 isochoric pressure formulas
Post-Breakage ContainmentDisintegrates into small, relatively blunt granular dice (minimum 40 particles per 50mm × 50mm square per EN 12150-1), drastically reducing laceration riskGlass panes crack upon high impact but fragments adhere tenaciously to the elastomeric interlayer; aperture remains sealed, preventing human fall-through or falling debrisDepends on selected plies; safety glass required on inner or outer depending on impact zone and fall risk
Typical Thermal Ug (W/m²K)5.7 to 5.8 W/m²K (monolithic vertical, EN 673) — requires IGU assembly with Low-E coating for thermal compliance5.4 to 5.6 W/m²K monolithic; 1.0 to 1.3 W/m²K in sealed insulating units1.0 to 1.2 W/m²K (Double Glazed 28mm Argon + Soft Coat Low-E); 0.5 to 0.7 W/m²K (Triple Glazed 44mm Krypton/Argon)
Acoustic Reduction (Rw dB)Rw 29 (-2; -3) dB (4mm) to Rw 35 (-1; -2) dB (12mm) — exhibits marked coincidence dip at critical frequenciesRw 33 dB to Rw 42 dB (acoustic PVB achieves +3 to +5 dB reduction over monolithic glass of equivalent mass)Rw 31 (-2; -5) dB (standard 4-16-4) up to Rw 46 (-2; -6) dB (dissimilar thicknesses + acoustic laminated pane)
Solar Factor (g-value)Conditional / Base Float (~0.85)Conditional / Base Float (~0.85)0.28 to 0.65 depending on Low-E vs Solar Control coating selection
Can Be Cut / Drilled After Fabrication? STRICTLY NO (Pre-furnace only) STRICTLY NO (Pre-furnace only) STRICTLY NO (Pre-furnace only)
Heat Soak Testing (HST)Recommended to BS EN 14179 (NiS risk mitigation)Recommended to BS EN 14179 (NiS risk mitigation)Recommended to BS EN 14179 (NiS risk mitigation)
Next Procurement Step

Direct supply specification for cut-to-size toughened panels or local glazier installation quotes.

Read full technical specification

Specify interlayer performance requirements and reach qualified regional architectural laminators.

Read full technical specification

Calculate whole-window U-value and obtain commercial sealed unit supply quotations.

Read full technical specification
Performance figures based on European Standard test methodologies (EN 410, EN 673, EN ISO 717-1). Whole-system calculations required for Building Control sign-off.